Dual fuel means the house keeps a furnace (or sometimes a boiler) and adds a heat pump, usually in place of a straight air conditioner. The heat pump handles cooling and the milder heating hours. The furnace takes the cold snaps.

There are two different “balance points,” and mixing them up is how people get surprised.

  • The capacity (thermal) balance point is about physics: the outdoor temperature where the heat pump’s output equals the house’s heat loss. Below that, you need backup heat to hold the setpoint.
  • The economic balance point is about money: the point at which a unit of delivered heat costs the same from the heat pump as from the furnace.

They are not the same. A heat pump can still heat the house at a temperature where the furnace is cheaper to run.

ENERGY STAR’s clean-heating page describes this dual-fuel arrangement as a common option when a relatively new furnace is paired with a new heat pump instead of a new air conditioner. This article is about the operating-cost half of that idea, with a Western New York example that uses published rates and states every assumption.

The arithmetic (so you can check it)

Use consistent units.

  • 1 kilowatt-hour (kWh) = 3,412 Btu (a physical conversion, not a utility tariff).
  • 1 therm = 100,000 Btu.
  • 1 dekatherm (Dth) = 10 therms (1,000,000 Btu).
  • National Fuel bills this residential sales rate in Mcf (volume). For November 2026, National Fuel’s published New York Division conversion is 1.031 Dth per Mcf, so 1 Mcf contains about 10.31 therms. That is a tighter figure than the usual 1 Mcf ≈ 10 therms assumption, which would apply only if the gas were exactly 1,000 Btu per cubic foot.

Cost to deliver 100,000 Btu of heat:

  • Furnace: (gas price per therm) ÷ AFUE
  • Heat pump: (electric price per kWh) × (100,000 ÷ 3,412) ÷ COP

Set those equal and solve for the break-even COP:

Break-even COP = (electric $/kWh × 29.308) ÷ (gas $/therm ÷ AFUE)

If the heat pump’s COP at the current outdoor temperature is higher than that break-even COP, the heat pump is the cheaper heat. If it is lower, the furnace is cheaper. Monthly customer charges are left out of this comparison when the house would be paying them anyway (you already have electric service, and in a dual-fuel house you are also keeping gas service).

Assumptions used in this example (dated)

These are not “typical annual rates.” They are specific published figures, checked on November 27, 2026.

Electricity — National Grid Upstate New York, residential SC-1, Load Zone A (West / Frontier), November 2026, exclusive of gross receipts taxes:

The previous version of this article used only the 10.013¢/kWh delivery charge plus the November 2026 Zone A ESCost and ESRM, or 16.395¢/kWh, and said that figure understated a real bill because the other published riders were omitted. Those riders are now included. The $19.00 monthly basic service charge is still left out of the per-kWh figure, because a dual-fuel house would pay it anyway.

Component ¢/kWh Official statement
Delivery charge 10.013 SC-1 service-rate page
Legacy Transition Charge −0.0548 Supply Service Charges No. 184
Transmission Revenue Adjustment 0.408 TRAS No. 219
Revenue Decoupling Mechanism −0.224 RDM No. 51
VDER value-stack cost recovery 1.307 Other Delivery Surcharges No. 15
Earnings Adjustment Mechanism −0.002 ODS No. 15
Electric Vehicle Make-Ready 0.147 ODS No. 15
Energy Storage Surcharge 0.000 ODS No. 15
Arrears Management Phase 1 0.000 ODS No. 15
Arrears Management Phase 2 0.076 ODS No. 15
Dynamic Load Management 0.0251 ODS No. 15
Rate Adjustment Mechanism 0.582 ODS No. 15
Proactive Planning Surcharge 0.016 ODS No. 15
System Benefits Charge 0.2981 SBC No. 29
Clean Energy Standard Delivery (including IEDR Phase 2) 0.019 CESD No. 6
Electricity Supply Cost, Zone A 6.291 Supply Service Charges No. 184
Electricity Supply Reconciliation Mechanism, Zone A 0.0910 Supply Service Charges No. 184
Clean Energy Standard Supply 0.668 CESS No. 10
Merchant Function Charge (calculated from MFC No. 23) 0.2326 MFC No. 23
Sum of published per-kWh charges 19.893 Before gross receipts taxes

The Merchant Function Charge is not a single flat rate. For SC-1 it is 2.29% of (ESCost + ESRM + CESS), plus 0.285% of (ESCost + ESRM), plus a $0.00012/kWh procurement charge and a $0.00041/kWh credit-and-collection charge, which adds to 0.2326¢/kWh at these November 2026 Zone A supply rates.

Added together, the published per-kWh charges equal 19.893¢/kWh. This is still not a complete all-in bill, because every National Grid statement above is exclusive of gross receipts taxes, which vary by municipality and would raise a real Buffalo-area price. Using a pre-tax energy charge still makes the heat pump look slightly better than a taxed bill would. A higher all-in rate would raise the break-even COP further.

Natural gas — National Fuel New York Division, Residential Rate Summary, November 2026 (created November 2, 2026):

  • “All Over 5 Mcf” total sales rate: $6.66645 per Mcf.
  • National Fuel’s published New York Dth/Mcf conversion for November 2026 is 1.031, so 1 Mcf ≈ 10.31 therms.
  • Marginal rate once a heating month is already past 5 Mcf: 6.66645 ÷ 10.31 = $0.6466 per therm.

The same summary lists a much higher first-block charge (the first 0.4 Mcf totals $25.51, which includes a large fixed-style component) and a “Next 4.6 Mcf” rate of $9.88423 per Mcf. This example uses the tail block because that is the usual marginal cost of another therm of heating in a winter month for a house that already has gas heat. The summary states that it does not supersede the tariff. The Btu conversion is National Fuel’s published transportation-processing factor for that month; it is the official monthly heat-content figure available for turning a Mcf-priced sales rate into a per-therm energy price.

Furnace efficiency (an assumption, labeled as such): 95% AFUE. ENERGY STAR gas furnaces in New York must be 97% AFUE or greater; many existing furnaces are lower. The table below also shows 97% so you can see the sensitivity. This is not a claim about the furnace in your basement.

Heat-pump COP (not assumed as a single number): the break-even result is a COP. For context only, ENERGY STAR’s Cold Climate designation requires a COP of at least 1.75 at 5°F. A specific model’s COP at 40°F or 17°F has to come from that model’s ratings (NEEP or AHRI data), not from a guess in this article.

The worked result

Using 19.893¢/kWh, $0.6466/therm, and 95% AFUE:

  • Furnace cost per 100,000 Btu delivered: 0.6466 ÷ 0.95 = $0.681
  • Heat-pump cost per 100,000 Btu delivered: (0.19893 × 29.308) ÷ COP = $5.830 ÷ COP
  • Break-even COP: 5.830 ÷ 0.681 = about 8.6

That is a high COP compared with the ENERGY STAR 5°F floor of 1.75. In plain language, with these dated Western New York gas and (pre-tax) electric prices, midwinter heat-pump operation is usually more expensive than a reasonably efficient gas furnace. Shoulder-season hours can still favor the heat pump if its COP is high enough, and the heat pump still does the cooling.

Here is the same math at two official or assumed efficiencies, and at two COP values, using the same energy prices:

Delivered heat, 100,000 Btu Cost at the rates above
Gas furnace at 95% AFUE $0.68
Gas furnace at 97% AFUE (ENERGY STAR North minimum) $0.67
Heat pump at COP 1.75 (ENERGY STAR Cold Climate floor at 5°F) $3.33
Heat pump at COP 3.0 (an example mid-range COP, not a rating for a named model) $1.94
Heat pump at the break-even COP of about 8.6 $0.68
Electric resistance (COP 1.0) $5.83

The COP 3.0 row is only an illustration of the formula. It is not a performance claim for a particular unit. If your all-in electric rate is higher than 19.893¢/kWh — as it will be once local gross receipts taxes are added — every heat-pump and resistance row gets more expensive and the break-even COP rises further.

What this should change about a quote conversation

  • Ask for a dual-fuel price, not only “all-electric heat pump” or “furnace plus AC,” when the house already has gas.
  • Ask how the changeover is controlled (outdoor temperature, or a calculated economic switch) and what backup heat is.
  • If the design uses electric-resistance backup, look at the COP 1 line. That is not a winter bargain against National Fuel gas at these rates.
  • If the house is on oil or propane instead of gas, do not reuse this gas result. Those fuels are priced differently; this guide does not invent a Buffalo oil or propane price. Use the same formula with a current, dated fuel price and the correct Btu content.

What still needs a local check

Rates change monthly. Gross receipts taxes omitted from the 19.893¢ figure matter, and they vary by municipality. A real house also has thermostat setup, defrost, duct losses, and part-load behavior that a back-of-the-envelope COP cannot capture. Use this as a way to understand the tradeoff, then plug in your bills and the ratings on the equipment you are being quoted.