Short answer: leave a working heat pump on the normal Heat setting all winter. Emergency Heat is a manual setting meant for when the heat pump itself has failed or cannot run. It is not a stronger version of heat, and it is not a way to get through a cold snap on a system that is working.

Part of the confusion is vocabulary. Thermostats label two different things with similar words.

Auxiliary heat vs. Emergency Heat

Auxiliary (“Aux”) heat Emergency Heat
Who turns it on The thermostat or system controls, automatically You, manually
Heat pump during operation Keeps running and gets help Typically shut off or bypassed
What provides the heat Backup heat: usually electric resistance strips on an all-electric system, or the furnace on a dual-fuel system The same backup source, alone
Intended use Normal part of heating in cold weather, or when recovering from a big temperature change The heat pump is broken, frozen, or otherwise unable to run

That comparison follows the descriptions published by Trane, Bryant, and Carrier (linked below). Bryant adds that the actual operating sequence varies by system and thermostat, so your own equipment’s manual is the final word.

Why not run Emergency Heat all the time

The compressor is what makes a heat pump efficient. The ENERGY STAR Cold Climate requirement is a coefficient of performance (COP) of at least 1.75 at 5°F, which means at least 1.75 units of heat delivered for each unit of electricity (see our cornerstone guide). Electric resistance backup has a COP of 1. Switching to Emergency Heat on an all-electric system takes away the compressor’s multiplier.

The U.S. Department of Energy’s Federal Energy Management Program says the same about the resistance elements: because of their inefficient nature, use should be kept to a minimum, and thermostats designed for heat pumps that ramp the temperature up slowly, to avoid activating the resistance elements, should be installed.

In our dual-fuel balance-point example, 100,000 Btu of delivered heat cost $5.83 as electric resistance versus about $0.68 from a 95% gas furnace, using the dated Western New York rates in that article (November 2026 National Grid and National Fuel figures, exclusive of gross receipts taxes). Those rates will have changed since, and your rates will differ, but the shape of the gap is why the manual setting is expensive to leave on. Carrier calls it highly inefficient and expensive to run continuously.

When Emergency Heat is appropriate

  • The outdoor unit has stopped running, is iced over, or is making a fault noise, and the house is losing temperature.
  • A contractor tells you to use it while a repair is pending.
  • Your equipment’s manual or installer tells you to use it for a specific situation. Follow the documentation for your model.

If you use it, treat it as a temporary bridge and schedule service.

If backup heat seems to run too much

Frequent or long auxiliary heat is the real thing to look into. Common reasons, none of which we can diagnose from a distance:

  • Large setpoint jumps. A big morning setback recovery can call for backup. Trane notes a rise of more than 3–4 degrees can trigger it. DOE’s guidance favors thermostats that ramp slowly.
  • Defrost. Some systems use backup heat during defrost so the air does not blow cold.
  • Real capacity shortfall. If the heat pump is undersized for the house at design conditions, backup runs in cold weather by design. This is a quoting and load-calculation issue, covered in how to read an HVAC quote.
  • A fault. A dirty filter, blocked outdoor coil, wrong thermostat configuration, or low refrigerant can all push the system to backup.

Dual fuel changes the question

With dual fuel, the backup is a furnace, and the economics depend on your gas and electric prices, as in the balance-point guide. In that setup the useful question for your installer is not “when do I press Emergency Heat?” but “at what outdoor temperature or economic condition does the furnace take over automatically, and what is the setting?” You should never have to babysit the thermostat to stay warm.

What we are not claiming

  • We did not find a primary federal source that defines the Emergency Heat setting. The definitions here come from three manufacturers and are consistent with each other; your thermostat and equipment documentation govern.
  • We do not publish a “right” balance-point setting, aux lockout temperature, or strip-heat size. Those depend on the house and the equipment.